Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Battery replacement without tools
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Building Wiring Fault Indicator
This LED informs users of potentially dangerous wiring problems in the wall circuit.
Cold-start capable
Provides temporary battery power when the utility power is out.
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Extendable Run Time
Additional batteries can be added to provide power to the load for an extended period of time in the event of utility supply failure.
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Power-saving outlets
Automatically cuts power to idle equipment to conserve electricity.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Serial connectivity
Provides management of the UPS via a serial port.
Telephone dataline surge protection
Provides protection of connected equipment from power surges traveling on telephone lines.
Transformer-block spaced outlets
Protect equipment with input transformer blocks without blocking access to other receptacles.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
Energy Management Function
Energy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Disconnected battery notification
Warns when a battery is not available to provide backup power.
USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.
Simple battery replacement
Increases UPS availability by allowing quick, easy battery replacement.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Energy Management Function
Energy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.
Customizable voltage-transfer points
Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Customizable voltage sensitivity
Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Cold-start capable
Provides temporary battery power when the utility power is out.
Transformer-block spaced outlets
Protect equipment with input transformer blocks without blocking access to other receptacles.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Andorra , United Arab Emirates , Afghanistan , Antigua and Barbuda , Albania , Armenia , Angola , Austria , Australia , Azerbaijan , Bosnia and Herzegovina , Bangladesh , Belgium , Burkina Faso , Bulgaria , Bahrain , Burundi , Benin , Brunei , Bolivia , Brazil , Bhutan , Botswana , Belarus , The Democratic Republic Of Congo , Central African Republic , Congo , Switzerland , Côte d'Ivoire , Cook Islands , Chile , Cameroon , Serbia and Montenegro , Cyprus , Czech Republic , Germany , Djibouti , Denmark , Dominica , Algeria , Estonia , Egypt , Western Sahara , Eritrea , Spain , Ethiopia , Finland , Fiji , France , Gabon , United Kingdom , Georgia , French Guiana , Ghana , Gibraltar , Gambia , Guinea , Guadeloupe , Equatorial Guinea , Greece , Hong Kong , Croatia , Hungary , Indonesia , Ireland , Israel , Iraq , Iran , Iceland , Italy , Jordan , Kenya , Cambodia , South Korea , Kuwait , Cayman Islands , Kazakhstan , Lebanon , Liechtenstein , Sri Lanka , Liberia , Lesotho , Lithuania , Luxembourg , Latvia , Morocco , Moldova , Macedonia , Mali , Myanmar , Mongolia , Martinique , Mauritania , Malta , Malawi , Malaysia , Mozambique , Namibia , Niger , Nigeria , Netherlands , Norway , Nepal , New Zealand , Oman , Peru , Papua New Guinea , Philippines , Pakistan , Poland , Portugal , Paraguay , Romania , Russia , Rwanda , Saudi Arabia , Sudan , Sweden , Singapore , Slovenia , Slovakia , Sierra Leone , Senegal , Somalia , Suriname , Chad , Togo , Thailand , Tajikistan , Turkmenistan , Tunisia , TP , Turkey , Tanzania , Ukraine , Uganda , Uruguay , Uzbekistan , Vietnam , Yemen , South Africa , Zambia , Zimbabwe
Output
Output power capacity | 865Watts / 1.5 kVA |
Max Configurable Power (Watts) | 865Watts / 1.5 kVA |
Nominal Output Voltage | 230V |
Output Frequency (sync to mains) | 50/60Hz +/- 3 Hz |
Load Crest Factor | 3 : 1 |
Topology | Line Interactive |
Waveform type | Stepped approximation to a sinewave |
Output Connections
(8) IEC 320 C13 (Battery Backup)
(2) IEC Jumpers (Battery Backup)
(5)IEC 320 C13 (selector_surgetitle)
Transfer Time | 10ms typical : 12ms maximum |
Input
Nominal Input Voltage | 230V |
Input frequency | 50/60 Hz +/- 3 Hz (auto sensing) |
Input Connections | IEC-320 C14 |
Input voltage range for main operations | 176 - 294V |
Input voltage adjustable range for mains operation | 156 - 300V |
Number of Power Cord s | 1 |
Batteries & Runtime
Battery type | Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof | |
Typical recharge time | 8hour(s) | |
Replacement Battery | APCRBC124 | |
Expected Battery Life (years) | 3 - 5 | |
RBC Quantity | 1 | |
Extended Run Options | APC-Power-Saving-Back-UPS-Pro-1500-230V | |
Runtime | View Runtime Graph | View Runtime Chart |
Efficiency | View Efficiency Graph |
Communications & Management
Interface Port(s) | Optional Simple Signalling RS232 cable , USB |
Control panel | Multi-function LCD status and control console |
Audible Alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Surge Protection and Filtering
Surge energy rating | 441Joules |
Data Line Protection | Analog phone line for phone/fax/modem/DSL (RJ-11 connector), Network line - 10/100/1000 Base-T Ethernet (RJ-45 connector) |
Filtering | Full time multi-pole noise filtering :10% of IEEE surge let-thgouh : zero clamping response time: instantaneous |
Physical
Maximum Height | 301mm , 30.1CM |
Maximum Width | 112mm , 11.2CM |
Maximum Depth | 380mm , 38.0CM |
Net Weight | 12.7KG |
Shipping weight | 14.3KG |
Shipping Height | 387mm , 38.7CM |
Shipping Width | 238mm , 23.8CM |
Shipping Depth | 488mm , 48.8CM |
Color | Black |
Master Carton Units | 1.0 |
Units per Pallet | 20.0 |
SCC Codes | 1073130426874 8 |
Environmental
Operating Temperature | 0 - 40 °C |
Operating Relative Humidity | 0 - 95 % |
Operating Elevation | 0-9000meters |
Storage Temperature | -15 - 45 °C |
Storage Relative Humidity | 0 - 95 % |
Storage Elevation | 0-15000meters |
Audible noise at 1 meter from surface of unit | 45.0dBA |
Conformance
Approvals | A-tick, C-tick, CE, GOST, GS Mark, Telepermit, TUV |
Sustainable Offer Status
RoHS | Compliant |
REACH | REACH: Contains No SVHCs |
PEP | Available in Documentation tab |
EOLI | Available in Documentation tab |