+964 750 905 1010
info [at] helptechco [dot] com
B2B

  • 1500
  • Back-UPS
  • BR1500GI

BR1500GI Features
APC Power-Saving Back-UPS Pro 1500, 230V
High-Performance Computer and Electronics UPS for Premium Power Protection
Includes: CD with software, Qty 1- Detachable IEC Power Cord, Telephone Cable, USB cable, User Manual, Warranty card

Adjustable voltage sensitivity

Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Adjustable voltage-transfer points

Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.

Audible alarms

Provides notification of changing utility power and UPS power conditions

Automatic self-test

Periodic battery self-test ensures early detection of a battery that needs to be replaced

Battery failure notification

Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Battery replacement without tools

Enables fast battery replacement, lowering Mean Time to Repair (MTTR).

Battery-protected and surge-only outlets

Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

Boost and Trim Automatic Voltage Regulation (AVR)

Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).

Building Wiring Fault Indicator

This LED informs users of potentially dangerous wiring problems in the wall circuit.

Cold-start capable

Provides temporary battery power when the utility power is out.

Dataline surge protection

Provides protection of connected equipment from power surges on the data lines.

Disconnected battery notification

Warns when a battery is not available to provide backup power.

Extendable Run Time

Additional batteries can be added to provide power to the load for an extended period of time in the event of utility supply failure.

Green mode

Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

Hot-swappable batteries

Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Intelligent battery management

Maximizes battery performance, life, and reliability through intelligent, precision charging.

LCD graphics display

Text and mimic diagrams that display modes of operation, system parameters and alarms.

Power-saving outlets

Automatically cuts power to idle equipment to conserve electricity.

Resettable circuit breaker

Easy recovery from overloads; no need to replace a fuse.

Safety-agency approved

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Serial connectivity

Provides management of the UPS via a serial port.

Telephone dataline surge protection

Provides protection of connected equipment from power surges traveling on telephone lines.

Transformer-block spaced outlets

Protect equipment with input transformer blocks without blocking access to other receptacles.

USB connectivity

Provides management of the UPS via a USB port (not available on all models).

User-replaceable batteries

Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Back-UPS Pro Features & Benefits
Marketing Features

Battery-protected and surge-only outlets

Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

Boost Automatic Voltage Regulation (AVR)

Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.

LCD Status Display

Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.

Energy Management Function

Energy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.

Green mode

Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

Safety

Safety-agency approved

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Manageability

LCD Status Display

Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.

Audible alarms

Provides notification of changing utility power and UPS power conditions

Disconnected battery notification

Warns when a battery is not available to provide backup power.

USB connection

Use your PC to access additional power protection and management features for your UPS via a USB Port.

Serviceability

Simple battery replacement

Increases UPS availability by allowing quick, easy battery replacement.

Resettable circuit breaker

Easy recovery from overloads; no need to replace a fuse.

Availability

Boost and Trim Automatic Voltage Regulation (AVR)

Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).

Energy Management Function

Energy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.

Customizable voltage-transfer points

Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.

Green mode

Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

Intelligent battery management

Maximizes battery performance, life, and reliability through intelligent, precision charging.

Customizable voltage sensitivity

Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.

Battery failure notification

Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Cold-start capable

Provides temporary battery power when the utility power is out.

Transformer-block spaced outlets

Protect equipment with input transformer blocks without blocking access to other receptacles.

Automatic self-test

Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Protection

Dataline surge protection

Provides protection of connected equipment from power surges on the data lines.

Battery and surge protected outlets

Back up and protect your hardware and data during power outages, surges and spikes.

Surge only outlets

Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.

Product Distribution

Andorra , United Arab Emirates , Afghanistan , Antigua and Barbuda , Albania , Armenia , Angola , Austria , Australia , Azerbaijan , Bosnia and Herzegovina , Bangladesh , Belgium , Burkina Faso , Bulgaria , Bahrain , Burundi , Benin , Brunei , Bolivia , Brazil , Bhutan , Botswana , Belarus , The Democratic Republic Of Congo , Central African Republic , Congo , Switzerland , Côte d'Ivoire , Cook Islands , Chile , Cameroon , Serbia and Montenegro , Cyprus , Czech Republic , Germany , Djibouti , Denmark , Dominica , Algeria , Estonia , Egypt , Western Sahara , Eritrea , Spain , Ethiopia , Finland , Fiji , France , Gabon , United Kingdom , Georgia , French Guiana , Ghana , Gibraltar , Gambia , Guinea , Guadeloupe , Equatorial Guinea , Greece , Hong Kong , Croatia , Hungary , Indonesia , Ireland , Israel , Iraq , Iran , Iceland , Italy , Jordan , Kenya , Cambodia , South Korea , Kuwait , Cayman Islands , Kazakhstan , Lebanon , Liechtenstein , Sri Lanka , Liberia , Lesotho , Lithuania , Luxembourg , Latvia , Morocco , Moldova , Macedonia , Mali , Myanmar , Mongolia , Martinique , Mauritania , Malta , Malawi , Malaysia , Mozambique , Namibia , Niger , Nigeria , Netherlands , Norway , Nepal , New Zealand , Oman , Peru , Papua New Guinea , Philippines , Pakistan , Poland , Portugal , Paraguay , Romania , Russia , Rwanda , Saudi Arabia , Sudan , Sweden , Singapore , Slovenia , Slovakia , Sierra Leone , Senegal , Somalia , Suriname , Chad , Togo , Thailand , Tajikistan , Turkmenistan , Tunisia , TP , Turkey , Tanzania , Ukraine , Uganda , Uruguay , Uzbekistan , Vietnam , Yemen , South Africa , Zambia , Zimbabwe

BR1500GI
/ /
APC
/

 Output

Output power capacity 865Watts / 1.5 kVA
Max Configurable Power (Watts) 865Watts / 1.5 kVA
Nominal Output Voltage 230V
Output Frequency (sync to mains) 50/60Hz +/- 3 Hz
Load Crest Factor 3 : 1
Topology Line Interactive
Waveform type Stepped approximation to a sinewave

Output Connections

(8) IEC 320 C13 (Battery Backup)
(2) IEC Jumpers (Battery Backup)
(5)IEC 320 C13 (selector_surgetitle)

Transfer Time 10ms typical : 12ms maximum

Input

Nominal Input Voltage 230V
Input frequency 50/60 Hz +/- 3 Hz (auto sensing)
Input Connections IEC-320 C14
Input voltage range for main operations 176 - 294V
Input voltage adjustable range for mains operation 156 - 300V
Number of Power Cord s 1

Batteries & Runtime

Battery type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time 8hour(s)
Replacement Battery APCRBC124
Expected Battery Life (years) 3 - 5
RBC Quantity 1
Extended Run Options APC-Power-Saving-Back-UPS-Pro-1500-230V
Runtime View Runtime Graph View Runtime Chart
Efficiency View Efficiency Graph

Communications & Management

Interface Port(s) Optional Simple Signalling RS232 cable , USB
Control panel Multi-function LCD status and control console
Audible Alarm Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm

Surge Protection and Filtering

Surge energy rating 441Joules
Data Line Protection Analog phone line for phone/fax/modem/DSL (RJ-11 connector), Network line - 10/100/1000 Base-T Ethernet (RJ-45 connector)
Filtering Full time multi-pole noise filtering :10% of IEEE surge let-thgouh : zero clamping response time: instantaneous

Physical

Maximum Height 301mm , 30.1CM
Maximum Width 112mm , 11.2CM
Maximum Depth 380mm , 38.0CM
Net Weight 12.7KG
Shipping weight 14.3KG
Shipping Height 387mm , 38.7CM
Shipping Width 238mm , 23.8CM
Shipping Depth 488mm , 48.8CM
Color Black
Master Carton Units 1.0
Units per Pallet 20.0
SCC Codes 1073130426874 8

Environmental

Operating Temperature 0 - 40 °C
Operating Relative Humidity 0 - 95 %
Operating Elevation 0-9000meters
Storage Temperature -15 - 45 °C
Storage Relative Humidity 0 - 95 %
Storage Elevation 0-15000meters
Audible noise at 1 meter from surface of unit 45.0dBA

Conformance

Approvals A-tick, C-tick, CE, GOST, GS Mark, Telepermit, TUV

Sustainable Offer Status

RoHS Compliant
REACH REACH: Contains No SVHCs
PEP Available in Documentation tab
EOLI Available in Documentation tab
 
BR1500GI
/ /
APC
/
Top