Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Automatic Voltage Regulation (AVR)
Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Telephone dataline surge protection
Provides protection of connected equipment from power surges traveling on telephone lines.
USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.
LED status display
Quickly understand unit and power status with visual indicators.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Andorra , United Arab Emirates , Albania , Armenia , Angola , Austria , Azerbaijan , Bosnia and Herzegovina , Belgium , Burkina Faso , Bulgaria , Bahrain , Burundi , Benin , Bolivia , Botswana , Belarus , The Democratic Republic Of Congo , Central African Republic , Congo , Switzerland , Côte d'Ivoire , Chile , Cameroon , Serbia and Montenegro , Cyprus , Czech Republic , Germany , Djibouti , Denmark , Algeria , Estonia , Egypt , Western Sahara , Eritrea , Spain , Ethiopia , Finland , France , Gabon , United Kingdom , Georgia , French Guiana , Ghana , Gibraltar , Gambia , Guinea , Guadeloupe , Equatorial Guinea , Greece , Croatia , Hungary , Ireland , Israel , Iraq , Iran , Iceland , Italy , Jordan , Kenya , Kuwait , Kazakhstan , Lebanon , Liechtenstein , Liberia , Lesotho , Lithuania , Luxembourg , Latvia , Morocco , Moldova , Madagascar , Macedonia , Mali , Mongolia , Martinique , Mauritania , Malta , Mauritius , Malawi , Mozambique , Namibia , Niger , Nigeria , Netherlands , Norway , Oman , Peru , Pakistan , Poland , Portugal , Paraguay , Qatar , Reunion , Romania , Russia , Rwanda , Saudi Arabia , Sudan , Sweden , Slovenia , Slovakia , Sierra Leone , Senegal , Somalia , Suriname , Turks And Caicos Islands , Chad , Togo , Tajikistan , Turkmenistan , Tunisia , Turkey , Ukraine , Uganda , Uruguay , Uzbekistan , Yemen , Mayotte , South Africa , Zambia , Zimbabwe
Output
Output power capacity | 700Watts / 1.4 kVA |
Max Configurable Power (Watts) | 700Watts / 1.4 kVA |
Nominal Output Voltage | 230V |
Output Frequency (sync to mains) | 50/60 Hz +/-1 Hz |
Output Frequency (not synced) | 50/60 Hz +/-1 Hz |
Topology | Line Interactive |
Waveform type | Stepped approximation to a sinewave |
Output Connections
(2) IEC Jumpers (Battery Backup)
(6) IEC 320 C13 (Battery Backup)
Transfer Time | 8ms typical : 10 ms maximum |
Input
Nominal Input Voltage | 230V |
Input frequency | 50/60 Hz +/- 3 Hz (auto sensing) |
Input Connections | IEC-320 C14 |
Cord Length | 1.22meters |
Input voltage range for main operations | 150 - 280 V |
Number of Power Cords | 1 |
Type of Input Protection Required | 3-pole breaker |
Maximum Input Current | 6.0A |
Input Power Factor at Full Load | 0.5 |
Batteries & Runtime
Battery type | Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof | |
Typical recharge time | 8hour(s) | |
Expected Battery Life (years) | 2 - 5 | |
Runtime | View Runtime Graph | View Runtime Chart |
Efficiency | View Efficiency Graph |
Communications & Management
Interface Port(s) | USB |
Control panel | LED status display with On Line : On Battery : Replace Battery and Overload indicators |
Audible Alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Surge Protection and Filtering
Surge energy rating | 273Joules |
Data Line Protection | RJ-11 Modem/Fax protection |
Physical
Maximum Height | 215mm , 21.5CM |
Maximum Width | 130mm , 13.0CM |
Maximum Depth | 336mm , 33.6CM |
Net Weight | 12.0KG |
Shipping weight | 12.94KG |
Shipping Height | 295mm , 29.5CM |
Shipping Width | 245mm , 24.5CM |
Shipping Depth | 440mm , 44.0CM |
Color | Black |
Environmental
Operating Temperature | 0 - 40 °C |
Operating Relative Humidity | 0 - 95% non-condensing % |
Operating Elevation | 0-3000meters |
Storage Temperature | -15 - 40 °C |
Storage Relative Humidity | 0 - 95% non-condensing % |
Storage Elevation | 0-9000meters |
Audible noise at 1 meter from surface of unit | 45.0dBA |
Conformance
Approvals | A-tick, C-tick, CE, IEC 62040-1-1, Telepermit |