Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Battery replacement without tools
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Cold-start capable
Provides temporary battery power when the utility power is out.
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
EMI and RFI noise filtering
Reduces line noise that can cause data loss and keyboard errors.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Audible alarms
Provides notification of changing utility power and UPS power conditions
LED status indicators
Quickly understand unit and power status with visual indicators.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Albania , Angola , Austria , Bosnia and Herzegovina , Bulgaria , Benin , Serbia and Montenegro , Germany , Estonia , Egypt , Ethiopia , Finland , Guinea , Greece , Croatia , Hungary , Israel , Iran , Iceland , Lithuania , Luxembourg , Latvia , Morocco , Macedonia , Namibia , Netherlands , Norway , Pakistan , Romania , Rwanda , Sweden , Slovenia , Suriname , Togo , Tunisia , Turkey
Output
Output power capacity | 405Watts / 700VA |
Max Configurable Power (Watts) | 405Watts / 700VA |
Nominal Output Voltage | 230V |
Output Frequency (sync to mains) | 47 - 63 Hz |
Output Frequency (not synced) | 50Hz +/- 0.1% for 50Hz nominal |
Topology | Standby |
Waveform Type | Stepped approximation to a sinewave |
Output Connections
(4) Schuko CEE 7 (selector_surgetitle)
(4) IEC 320 C19 (Battery Backup)
Output Voltage Tolerance | +/- 5% static and 100% load step |
Transfer Time | 6ms typical: 10ms maximum |
Input
Nominal Input Voltage | 230V |
Input frequency | 50/60 Hz +/- 5 Hz (auto sensing) |
Input Connections | Schuko CEE 7/7P |
Cord Length | 1.83meters |
Input voltage range for main operations | 180 - 266V |
Maximum Input Current | 10.0A |
Batteries & Runtime
Battery type | Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leakproof | |
Typical recharge time | 16hour(s) | |
Replacement Battery | RBC17 | |
Expected Battery Life (years) | 3 - 5 | |
Runtime | View Runtime Graph | View Runtime Chart |
Efficiency | View Efficiency Graph |
Communications & Management
Interface Port(s) | USB |
Control panel | LED status display with On Line: On Battery: Replace Battery and Overload indicators |
Surge Protection and Filtering
Surge energy rating | 310Joules |
Data Line Protection | Analog phone line for phone/fax/modem/DSL (RJ-11 connector), Network line - 10/100 Base-T Ethernet (RJ-45 connector) |
Filtering | Full-time multi-pole noise filtering: 5% IEEE surge let-through: zero clamping response time: meets UL 1449 |
Physical
Maximum Height | 89mm, 8.9CM |
Maximum Width | 224mm , 22.4CM |
Maximum Depth | 311mm, 31.1CM |
Net Weight | 6.93KG |
Shipping weight | 7.84KG |
Shipping Height | 127mm, 12.7CM |
Shipping Width | 279mm, 27.9CM |
Shipping Depth | 400mm, 40.0CM |
Color | Black |
Master Carton Dimensions (Length x Width x Height) | 324mm |
Master Carton Units | 2.0 |
Master Carton Weight | 16.36 |
Pallet Dimensions | 48inches |
# of Layers per Pallet | 4.0 |
# of Units per Layer per Pallet | 20.0 |
Pallet Weight | 1400.0lbs. |
Units per Pallet | 48.0 |
SCC Codes | 1073130427170 0 |
Environmental
Operating Temperature | 0 - 40 °C |
Operating Relative Humidity | 0 - 95 % |
Operating Elevation | 0-3000meters |
Storage Temperature | -15 - 40 °C |
Storage Relative Humidity | 0 - 95 % |
Storage Elevation | 0-15000meters |
Audible noise at 1 meter from surface of unit | 40.0dBA |
Conformance
Approvals | CE |
Sustainable Offer Status
RoHS | Compliant |
REACH | REACH: Contains No SVHCs |
PEP | Available in Documentation tab |