in stock

  • True double conversion wide input voltage (110 - 300V)
  • Smart fan-speed control design
  • Eco mode energy saving
  • Optional powerful charger for battery backup extension
  • Adjustable battery number
  • Common battery for parallel operation
  • POU6K#16B7A

Power Solid 6KVa Single Phase Online UPS

- True double conversion wide input voltage (110 - 300V)
- Smart fan-speed control design
- Eco mode energy saving
- Optional powerful charger for battery backup extension
- Adjustable battery number
- Common battery for parallel operation

POU6K#16B7A
/ /
PowerSolid
/
Model Power Solid 6KVa
Capacity (Va/Watt) 6000 VA / 4800 Watt
Input
Voltage Range Low Line Loss 110 VAC ± 3 % at 50% Load; 176 VAC ± 3 % at 100% Load
Low Line Comeback Low Line Loss Voltage + 10V
High Line Loss 300 VAC ± 3 %
High Line Comeback High Line Loss Voltage - 10V
Frequency Range 46Hz - 54 Hz@ 50Hz system/ 56Hz - 64 Hz@ 60 Hz system
Phase Single phase neutral and ground
Power Factor ≥ 0.99 at 100% load
Output
Output Voltage 208 / 220 / 230 / 240 VAC (Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC)
AC Voltage Regulation ±1%
Frequency Range (Synchronized Range) 46 HZ~ 54 Hz@ 50Hz system/ 56Hz ~ 64Hz@ 60Hz system
Frequency Range (Batt. Model) 50 Hz± 0.1 Hz or 60Hz± 0.1 Hz
Overload AC mode 100% ~ 110%: 30min ; 110% ~ 130%: 5min; > 130%: 10sec
Battery mode 100% ~ 110%: 3min ; 110% ~ 130%: 30sec; > 130%: 10sec
Current Crest Ratio 3:1 Max.
Harmonic Distortion ≥ 3% THD ( Linear Load ) ≥ 5% THD ( Non-linear Load )
Transfer Time AC to Battery Oms
Inverter to Bypass
Efficiency
AC Mode ≥ 92 %
Battery Mode ≥ 90 %
Battery
Standard Model Battery Type 12V / 7 Ah x16
Recharge Time 9 hours recovery to 90% capacity
Charging Current Default: 1 A± 10% 
Max.: 1 A, 2 A (adjustable)
Charging Voltage 218.4V± 1%
Long-run Model Battery Type Depending on applications
Numbers 16-18-20
Charging Current Default: 4A ± 10% max.: lA, 2A, 4A, 6A (Adjustable, 6A is only available for 16 pcs batteries)
Charging Voltage 218.4V ± 1 % (based on 16 pcs batteries)
Physical
Standard Model with Bat. Dimension, D x W x H 442 x 190 x 688 (mm)
Net Weight (kgs) 61
Long-run Model Dimension, D x W x H 442 x 190 x 318 (mm)
Net Weight (kgs) 12
Environment
Operation Temperature 0 ~ 50°C
(battery life cycle will be shorten when temperature is above 25°C) 
Operation Humidity <95% and non-condensing
Operation Altitude <1000 m
Acoustic Noise Level Less than 55dB@ 1 Meter
Management
Smart RS-232 or USB Supports Windows® 2000/2003/XP/Vista/2008/7/8,Linux, Unix and MAC
Optional SNMP Power management from SNMP manager and web browser